X2H03R9
X2H03R9 — Insertion of Intraluminal Device, Bioprosthetic Valve into Inferior Vena Cava, Percutaneous Approach, New Technology Group 9
Billable / specific codeICD-10-PCS
CMS abbreviated title: Insert Bioprosth Valve in Inf Vena Cava, Perc, New Tech 9
How X2H03R9 is built
Every ICD-10-PCS code is seven independent character positions. Each one is a separate decision, and the meaning of a character depends on the positions before it.
- XSectionNew Technology — What family of procedure this is
- 2Body systemWhich system it acts on
- HRoot operationThe objective — the verb of the procedure
- 0Body partThe specific site
- 3ApproachHow the site was reached
- RDeviceWhat was left in place, if anything
- 9QualifierA further distinction where one applies
Codes near X2H03R9
In CMS’s own ordering, which groups codes that differ by only the last character or two — usually the approach, device or qualifier.
- X2CR3T7Extirpation of Matter from Left Upper Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
- X2CS3T7Extirpation of Matter from Right Lower Extremity Artery using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
- X2CT3T7Extirpation of Matter from Left Lower Extremity Artery using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
- X2CU3T7Extirpation of Matter from Right Lower Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
- X2CV3T7Extirpation of Matter from Left Lower Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
- X2CY3T7Extirpation of Matter from Great Vessel using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
- X2H03BBInsertion of Volume Sensor Management Device into Inferior Vena Cava, Percutaneous Approach, New Technology Group 11
- X2H03R9Insertion of Intraluminal Device, Bioprosthetic Valve into Inferior Vena Cava, Percutaneous Approach, New Technology Group 9
- X2H13R9Insertion of Intraluminal Device, Bioprosthetic Valve into Superior Vena Cava, Percutaneous Approach, New Technology Group 9
- X2H13XBInsertion of Temporary Phrenic Nerve/Diaphragm Stimulation Electrodes into Superior Vena Cava, Percutaneous Approach, New Technology Group 11
- X2H20R9Insertion of Intraluminal Device, Bioprosthetic Valve into Right Femoral Vein, Open Approach, New Technology Group 9
- X2H30R9Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9
- X2H63V9Insertion of Dual-Chamber Intracardiac Pacemaker into Right Atrium, Percutaneous Approach, New Technology Group 9
- X2HK3V9Insertion of Dual-Chamber Intracardiac Pacemaker into Right Ventricle, Percutaneous Approach, New Technology Group 9
- X2HL0F9Insertion of Conduit to Short-term External Heart Assist System into Right Axillary Artery, Open Approach, New Technology Group 9
- X2HM0F9Insertion of Conduit to Short-term External Heart Assist System into Left Axillary Artery, Open Approach, New Technology Group 9