MCMedicalCodingSoftware
X2CV3T7

X2CV3T7Extirpation of Matter from Left Lower Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7

Billable / specific codeICD-10-PCS

CMS abbreviated title: Extirpate matter from LLE Vn, Comp-aid Mech Asp, New Tech 7

How X2CV3T7 is built

Every ICD-10-PCS code is seven independent character positions. Each one is a separate decision, and the meaning of a character depends on the positions before it.

  1. XSectionNew Technology — What family of procedure this is
  2. 2Body systemWhich system it acts on
  3. CRoot operationThe objective — the verb of the procedure
  4. VBody partThe specific site
  5. 3ApproachHow the site was reached
  6. TDeviceWhat was left in place, if anything
  7. 7QualifierA further distinction where one applies

Codes near X2CV3T7

In CMS’s own ordering, which groups codes that differ by only the last character or two — usually the approach, device or qualifier.

  • X2AL34BLeft Internal Carotid Artery Cerebral Embolic Filtration, Single Integrated Distal Filter, Percutaneous Approach, New Technology Group 11
  • X2CP3T7Extirpation of Matter from Abdominal Aorta using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CQ3T7Extirpation of Matter from Right Upper Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CR3T7Extirpation of Matter from Left Upper Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CS3T7Extirpation of Matter from Right Lower Extremity Artery using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CT3T7Extirpation of Matter from Left Lower Extremity Artery using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CU3T7Extirpation of Matter from Right Lower Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CV3T7Extirpation of Matter from Left Lower Extremity Vein using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2CY3T7Extirpation of Matter from Great Vessel using Computer-aided Mechanical Aspiration, Percutaneous Approach, New Technology Group 7
  • X2H03BBInsertion of Volume Sensor Management Device into Inferior Vena Cava, Percutaneous Approach, New Technology Group 11
  • X2H03R9Insertion of Intraluminal Device, Bioprosthetic Valve into Inferior Vena Cava, Percutaneous Approach, New Technology Group 9
  • X2H13R9Insertion of Intraluminal Device, Bioprosthetic Valve into Superior Vena Cava, Percutaneous Approach, New Technology Group 9
  • X2H13XBInsertion of Temporary Phrenic Nerve/Diaphragm Stimulation Electrodes into Superior Vena Cava, Percutaneous Approach, New Technology Group 11
  • X2H20R9Insertion of Intraluminal Device, Bioprosthetic Valve into Right Femoral Vein, Open Approach, New Technology Group 9
  • X2H30R9Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9
ICD-10-PCSFY2026