XRH63FA
XRH63FA: Insertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Approach, New Technology Group 10
Billable / specific codeICD-10-PCS
CMS abbreviated title: Insert Pdcl Ca/PK Stblz in Thor Jt, Perc, New Tech 10
How XRH63FA is built
Every ICD-10-PCS code is seven independent character positions. Each one is a separate decision, and the meaning of a character depends on the positions before it.
- XSectionNew Technology: What family of procedure this is
- RBody systemWhich system it acts on
- HRoot operationThe objective: the verb of the procedure
- 6Body partThe specific site
- 3ApproachHow the site was reached
- FDeviceWhat was left in place, if anything
- AQualifierA further distinction where one applies
Codes near XRH63FA
In CMS’s own ordering, which groups codes that differ by only the last character or two, usually the approach, device or qualifier.
- XRH40NCInsertion of Carbon/PEEK Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Open Approach, New Technology Group 12
- XRH43GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Percutaneous Approach, New Technology Group 11
- XRH43NCInsertion of Carbon/PEEK Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Percutaneous Approach, New Technology Group 12
- XRH44GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 11
- XRH44NCInsertion of Carbon/PEEK Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 12
- XRH60FAInsertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Open Approach, New Technology Group 10
- XRH60GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Thoracic Vertebral Joint, Open Approach, New Technology Group 11
- XRH60NCInsertion of Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Open Approach, New Technology Group 12
- XRH63FAInsertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Approach, New Technology Group 10
- XRH63GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Approach, New Technology Group 11
- XRH63NCInsertion of Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Approach, New Technology Group 12
- XRH64FAInsertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 10
- XRH64GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 11
- XRH64NCInsertion of Carbon/PEEK Spinal Stabilization Device into Thoracic Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 12
- XRH70FAInsertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into 2 to 7 Thoracic Vertebral Joints, Open Approach, New Technology Group 10
- XRH73FAInsertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into 2 to 7 Thoracic Vertebral Joints, Percutaneous Approach, New Technology Group 10
- XRH74FAInsertion of Pedicle Based Carbon/PEEK Spinal Stabilization Device into 2 to 7 Thoracic Vertebral Joints, Percutaneous Endoscopic Approach, New Technology Group 10