MCMedicalCodingSoftware
XRH10GB

XRH10GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervical Vertebral Joint, Open Approach, New Technology Group 11

Billable / specific codeICD-10-PCS

CMS abbreviated title: Insert Pedcl MoRe Stblz in Cerv Jt, Open, New Tech 11

How XRH10GB is built

Every ICD-10-PCS code is seven independent character positions. Each one is a separate decision, and the meaning of a character depends on the positions before it.

  1. XSectionNew Technology — What family of procedure this is
  2. RBody systemWhich system it acts on
  3. HRoot operationThe objective — the verb of the procedure
  4. 1Body partThe specific site
  5. 0ApproachHow the site was reached
  6. GDeviceWhat was left in place, if anything
  7. BQualifierA further distinction where one applies

Codes near XRH10GB

In CMS’s own ordering, which groups codes that differ by only the last character or two — usually the approach, device or qualifier.

  • XRGJ0CAFusion of Right Ankle Joint using Gyroid-Sheet Lattice Design Internal Fixation Device, Open Approach, New Technology Group 10
  • XRGK0B9Fusion of Left Ankle Joint using Open-truss Design Internal Fixation Device, Open Approach, New Technology Group 9
  • XRGK0CAFusion of Left Ankle Joint using Gyroid-Sheet Lattice Design Internal Fixation Device, Open Approach, New Technology Group 10
  • XRGL0B9Fusion of Right Tarsal Joint using Open-truss Design Internal Fixation Device, Open Approach, New Technology Group 9
  • XRGL0CAFusion of Right Tarsal Joint using Gyroid-Sheet Lattice Design Internal Fixation Device, Open Approach, New Technology Group 10
  • XRGM0B9Fusion of Left Tarsal Joint using Open-truss Design Internal Fixation Device, Open Approach, New Technology Group 9
  • XRGM0CAFusion of Left Tarsal Joint using Gyroid-Sheet Lattice Design Internal Fixation Device, Open Approach, New Technology Group 10
  • XRH10GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervical Vertebral Joint, Open Approach, New Technology Group 11
  • XRH13GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervical Vertebral Joint, Percutaneous Approach, New Technology Group 11
  • XRH14GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervical Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 11
  • XRH20GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Open Approach, New Technology Group 11
  • XRH23GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Approach, New Technology Group 11
  • XRH24GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Endoscopic Approach, New Technology Group 11
  • XRH40GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Open Approach, New Technology Group 11
  • XRH43GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Percutaneous Approach, New Technology Group 11
  • XRH44GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Percutaneous Endoscopic Approach, New Technology Group 11
ICD-10-PCSFY2026